The Wireless Direct Damper Controls are ideal for spaces where running wires may be difficult. An R80DWL wireless damper is installed between the flex duct and diffuser or register and is wired to a 24VAC transformer. A wireless thermostat, T200WLD, is installed on the wall and requires no wiring.
The user simply sets the mode in the thermostat to either heating or cooling to correspond to the type of call being made by the equipment. The thermostat will adjust the airflow into the space using the setpoint temperature to maintain the temperature. In the Off mode, the airflow defaults to the level set in the options.
Or, a wireless remote control, WRCD, can be used to wirelessly adjust the damper position from 100% open to fully closed enabling the occupant to control the airflow into the space.
How It Works
Contractor Resources
Click on the Resources link for contractor resources including videos, manuals, brochures and other materials for all Comfort365 products.
Where To Buy
Click on the Distributor link to find a distributor in your area. If there is not a distributor in your area, please contact us.
(949) 916-0945
26072 Merit Circle #110 / Laguna Hills, CA 92653 / 949-916-0945 / Fax 949-458-8502
eControls
Copyright 2017
Direct Damper Control Wireless Installation
Wireless, Programmable Thermostat
T200WLD
Wireless, Battery Operated Thermostat for damper control.
R80DWLXX
Wireless Damper
24VAC
Transformer
T200WLD
Wireless Thermostat
Wireless Damper
R80DWLXX
Damper, modulating, wireless, with XX diameter from 6 to 14 inches.
Wireless Direct Damper Control
An R80DV wired damper is installed between the flex duct and diffuser or register and is wired to a 24VAC transformer. A manual wall control, MWC, is installed on the wall and is wired to the damper. The MWC is used to adjust damper position from 100% open to fully closed enabling the occupant to control the airflow to provide optimum comfort when the space is occupied and reduce energy consumption when the space is vacant.
Wired Direct Damper Control
R80DWLXX
Wireless Damper
24VAC
Transformer
WRCD
Wireless Remote Control
Wireless Thermostat Installation
Wireless Remote Control Installation
Wireless Remote Control
WRCD
Wireless, Battery Operated Remote Control
Direct Damper Control Wired Installation
Wired Control
MWC
Manual Wall Control. Wired to damper using 3 low voltage wires.
Wired Damper
R80DVXX
Damper, variable position, wired, with XX diameter from 6 to 14 inches.
R80DVXX
Wireless Damper
24VAC
Transformer
MWC
Manual Wall Control
To 24VAC
Transformer
(2)
(X) Number of Wires
WRCD, Wireless Remote Control
T200WLD, Wireless Thermostat
R80DWL, Wireless Modulating Damper
HVAC
Equipment
To 24VAC
Transformer
R80DV, Variable Position Damper
MWC, Manual Wall Control
(X) Number of Wires
(2)
(3)
HVAC
Equipment
A80VP
Actuator, modulating,
Wired, 24VAC, 2.4VA.
A80WLD
Actuator, modulating,
Wired, 24VAC, 2.4VA.
Direct Damper Controls
Direct Damper Controls eliminate the overcooling and overheating found in many homes and commercial sites where a single thermostat controls multiple spaces. Direct Damper Controls allow a user to control the amount of air into a space by opening or closing the damper that is connected to the diffuser of register.
Media Rooms
Exam Rooms
Training Rooms
Offices
Garages
"I'm too cold when the air conditioning is on."
Direct Damper Controls improve comfort and productivity by enabling the occupant to adjust the airflow to their desired comfort level.
In a home, there may be certain rooms where less airflow is desired, such as a nursery or a grandparents room. Direct Damper Controls enable the occupant to select the airflow that is most desirable for the space.
Space is too cold or too warm for your customer.
Direct Damper Controls makes the space comfortable for every customer by adjusting the airflow to the customer's comfort level.
Heating or cooling a vacant room wastes energy.
Save energy using Direct Damper Controls to close the damper to an unused space and direct more airflow to the occupied spaces.
Rooms, such as a home theater or a garage, may only need airflow on occasion. Reducing airflow to these rooms saves energy.
Guest Room
Nurseries