A simple low-cost solution that uses the existing
thermostat wiring and provides comfort upstairs and downstairs without using zoning.
How It Works
Contractor Resources
Click on the Resources link for contractor resources including videos, manuals, brochures and other materials for all Comfort365 products.
Add On / Replacement
Where To Buy
Click on the Distributor link to find a distributor in your area. If there is not a distributor in your area, please contact us.
Comfort365 Wiring Hub Solution
Features
Easily Upgrade to WiFi
The Comfort365 can easily be upgraded to WiFi to provide homeowners with remote access to their home's heating and cooling system. The Comfort365 WiFi version simply
Nighttime Energy Savings
The Comfort365 includes Energy Star nighttime setback temperatures. For additional savings, homeowners can take advantage of the Nighttime Airflow option which uses the temperature sensor in the bedroom area to control heating
Meets Title 24
The Comfort365 has no effect on the HVAC equipment. The equipment operates at its rated airflow and return temperature.
and cooling calls and direct more airflow to the bedroom area at night and less airflow to the unoccupied living area.
plugs into the same subbase - no additional wiring needed. Also, only one Comfort365 WiFi thermostat is required compared to zoning which requires purchasing two WiFi thermostats.
Modern Touchscreen Thermostat
Homeowners will appreciate the modern, touch screen thermostat with high definition LCD display compared to the outdated, non-touch builder grade thermostats used in conventional zoning with small LCD displays.
Programmable Communicating Thermostats
Temperature Sensors
Damper
TS5WL Wireless Temp Sensor
1 or 2 sensors can be used.
Install (1) in Bedroom Hallway
and (1) in Master Bedroom.
C365C42
C365C42WF
Communicating Thermostat.
Communicating Thermostat.
WiFi Enabled.
TS510W
TS520W
R80CJXX
Wired temperature sensor for single sensor installations.
Wired temperature sensor for two sensor installations.
Damper, modulating, Plug&Play with XX diameter from 6 to 20 inches. Includes A80MJ actuator and 25 ft. plug&play cable.
A80MJ
Actuator, modulating,
Plug&Play, 24VAC, 2.4VA.
A common problem found in two-story homes is the uneven heating and cooling of the upstairs and downstairs. During the summer, the upstairs is too warm. During the winter, the downstairs is too cool. The Comfort365 solves the problem by dynamically adjusting the airflow based on the upstairs and downstairs temperatures.
A Comfort365 thermostat is installed in the living space, a wireless temperature sensor is installed in the bedroom space, modulating dampers are installed to control the airflow to the living space and the bedroom space and the Wiring Hub is installed at the equipment.
Every 2 minutes during heating and cooling calls, the C365 thermostat compares the temperature at the sensor and the temperature at the thermostat. If the temperatures are different, the Comfort365 automatically adjusts the modulating dampers 2% so that more airflow is directed to the space that needs it for a uniformly comfortable home.
eLink Radio Simplifies Installation
The ELR1 Radio Module plugs into the Wiring Hub and eliminates having to install new wiring between the Wiring Hub and the upstairs wireless sensor.
Comfort365 Wiring Hub
WH11
WH32
Use with gas/electric equipment, 1H/1C.
Use with gas/electric, heat pump and dual fuel heat pump equipment, 3H/2C.
TS5WL
Wireless temperature sensor for single or dual sensor installations. Requires ELR1.
ELR1
Plug-in radio module. Required when using wireless sensor.
TS3
Outdoor air temperature sensor. Required when using dual fuel heat pump equipment.
Wiring Hub solution using wireless upstairs temperature sensor(s)
Wiring Hub solution using wired upstairs temperature sensor(s)
Existing Thermostat
Wiring
(949) 916-0945
Contractor
Builder
Homeowner
26072 Merit Circle #110 / Laguna Hills, CA 92653 / 949-916-0945 / Fax 949-458-8502
eControls
Copyright 2017
Dampers are connected to wiring hub.
Typical savings of 46% in materials compared to a wireless zoning installation.
Only 9 wires and 2 Plug&Play cables to install
compared to 25 for zoning.
Easy upgrade to whole house comfort control -
Integrated control of whole house fans, economizers, fresh air, ERV/HRV and humidity by simply changing out the wiring hub.
Plug&Play dampers reduce wiring errors.
Uses existing thermostat cable to connect the
communicating thermostat to the wiring hub.
Wireless temperature sensors can be installed on
any wall and require no wiring.
Wired or wireless sensors can be used.
R80CJXX Upstairs
Plug&Play Damper
R80CJXX Upstairs
Plug&Play Damper
TS510W (1)
Wired Temp. Sensor,
Install in
Bedroom Hallway
TS520W (2)
Wired Temp. Sensors,
Install (1) in Bedroom Hallway and (1) in Master Bedroom
TS3 Outdoor Temp Sensor
Required when using
Dual Fuel Heat Pumps
C365C42 or C365C42WF
Communicating Thermostat
WH11 or WH32 Wiring Hub
HVAC
Equipment
R80CJXX Upstairs
Plug&Play Damper
R80CJXX Upstairs
Plug&Play Damper
HVAC
Equipment
C365C42 or C365C42WF
Communicating Thermostat
WH11 or WH32 Wiring Hub
TS3 Outdoor Temp Sensor
Required when using
Dual Fuel Heat Pumps
Automatic or manual airflow control.
One or two sensors can be used in the sleeping area.
42 to 57% material savings over zoning.
Eliminates installing zoning panel, DAT sensor and transformer.
Eliminates installing bypass.
Easy Upgrade to WiFi.
Reduced HERS testing and HERS testing failures eliminated.
Saves 30% in energy at night by using the sleeping area sensors and directing 30% more airflow to the sleeping area.
Home
Comfort365 for New Construction
Comfort365 for Add On/Replacement
Whole House Fan Controls for New Construction
Whole House Fan Controls for Add On/Replacement
Direct Damper Controls
Products
Comfort365
Whole House Fan Controls
Direct Damper Controls
Resources
About Us
Contact Us